Device-Managed Updates

Copy Markdown View Source

By default a device takes firmware whenever its deployment group sends it. Some devices should not: a machine mid-cycle, a vehicle in motion, a device whose owner has been given a say over when it restarts.

A device-managed device chooses when it takes firmware. It does not choose what — its deployment group still decides that. And it can never stop itself being reachable: only an operator can turn a device's updates off entirely.

The three modes

NervesHubLink.update_mode/1 reports how NervesHub is treating this device.

ModeWhat it means
:automaticThe deployment group sends firmware on its own schedule. The default.
:device_managedThe device asks for firmware itself, whenever suits it.
:offThe device takes no firmware except a manual push from an operator.

The mode lives on NervesHub, not here. That is deliberate: it survives a reboot without this library persisting anything, an operator can see and change it, and update_mode/1 always reports what NervesHub actually has rather than what this device last wanted.

It returns nil until NervesHub says. A server too old to know about update modes never will, and the device goes on taking updates exactly as before — so treat nil as "not device managed", never as an error.

Asking for an update

Two calls, and they are deliberately separate.

case NervesHubLink.check_for_update() do
  {:ok, %{available?: true, firmware_meta: meta}} ->
    Logger.info("firmware #{meta["version"]} is waiting")

  {:ok, %{available?: false}} ->
    :nothing_to_do

  {:error, reason} ->
    Logger.warning("could not check for firmware: #{inspect(reason)}")
end

check_for_update/1 is allowed in every mode, :off included. It is read-only, so a frozen device can still tell its user an update exists and an administrator needs to act. It reports metadata and no URL.

NervesHubLink.start_update()

start_update/1 is the one that fetches the firmware, and returns :ok once NervesHub has sent it. From there the update proceeds exactly as one the deployment group pushed, reporting through your NervesHubLink.Client.

The split matters. Firmware URLs are signed and time limited, so a device that checked at 02:00 and updated at 04:00 would find a dead link. The URL is fetched at the moment it is going to be used.

Being told to wait

Deployment groups pace their rollouts, and a device asking for firmware takes a slot in that pacing like any other update. A fleet that all wakes at 03:00 local would otherwise walk straight past it.

case NervesHubLink.start_update() do
  :ok -> :updating
  {:error, {:busy, minutes}} -> reschedule_in(minutes)
  {:error, reason} -> Logger.warning("update refused: #{inspect(reason)}")
end

Treat {:busy, minutes} as "not now" rather than "not ever", and do not retry sooner than it says.

{:error, :updating} means this device is already applying firmware; there is nothing to do but wait.

Choosing the mode from the device

A device may move itself between :automatic and :device_managed, and only once an operator has allowed it:

if NervesHubLink.managed_updates_allowed?() do
  NervesHubLink.set_update_mode(:device_managed)
end

managed_updates_allowed?/1 is off until an operator turns it on for this device in NervesHub. Ask before offering the choice, rather than offering a switch NervesHub will refuse.

A device can never set :off. That would let a device stop its own updates and leave nobody able to fix it remotely, so it stays an operator's decision.

set_update_mode/2 returns {:error, :not_permitted} when the operator has not allowed it, and {:error, :disconnected} when there is no connection to ask over. The change is not queued — an application that needs to converge should re-assert it when the connection comes back:

defmodule MyApp.NervesHubLinkClient do
  use NervesHubLink.Client

  @impl NervesHubLink.Client
  def connected() do
    if MyApp.Settings.automatic_updates?() do
      NervesHubLink.set_update_mode(:automatic)
    else
      NervesHubLink.set_update_mode(:device_managed)
    end

    :ok
  end
end

Re-asserting is safe to repeat, so this is the simplest way to keep a user-facing switch and NervesHub in step.

Putting it together

A device that updates only in its own maintenance window:

defmodule MyApp.UpdateWindow do
  use GenServer

  require Logger

  @check_interval :timer.minutes(30)

  def start_link(opts), do: GenServer.start_link(__MODULE__, opts, name: __MODULE__)

  @impl GenServer
  def init(_opts) do
    {:ok, %{}, {:continue, :schedule}}
  end

  @impl GenServer
  def handle_continue(:schedule, state) do
    Process.send_after(self(), :maybe_update, @check_interval)
    {:noreply, state}
  end

  @impl GenServer
  def handle_info(:maybe_update, state) do
    if MyApp.safe_to_restart?() do
      case NervesHubLink.check_for_update() do
        {:ok, %{available?: true}} -> apply_update()
        _ -> :ok
      end
    end

    {:noreply, state, {:continue, :schedule}}
  end

  defp apply_update() do
    case NervesHubLink.start_update() do
      :ok ->
        Logger.info("firmware update started")

      {:error, {:busy, minutes}} ->
        # The deployment group is at its concurrent update limit.
        Process.send_after(self(), :maybe_update, :timer.minutes(minutes))

      {:error, reason} ->
        Logger.warning("firmware update refused: #{inspect(reason)}")
    end
  end
end

Note what this does not do: it never decides which firmware to install, and it never turns updates off. Both remain with the deployment group and the operator, which is what keeps a fleet of these devices recoverable.

Requirements

Device-managed updates need a NervesHub that supports them, and are negotiated by device_api_version, which this library reports as 2.4.0. Against an older server the calls in this guide return errors and update_mode/1 stays nil; nothing else changes, and the device keeps taking updates as it always did.